560kW Temporary Chiller Hire
Heat exchanger
Air Handling Unit (AHU) used with Chiller
560kW Temporary Chiller Hire
Heat exchanger
Air Handling Unit (AHU) used with Chiller

Hard Wired

560kW Packaged Chiller Hire

Weight

3950kg

Dimensions (LxWxH)

5900mm x 2220mm x 2604mm

  • Planned or Emergency Hire
  • 24/7/365 Support
  • Rapid Response
  • Nationwide Delivery
  • Air Handling Units Available
  • Heat Exchangers Available
  • Large Stock
  • Free Site Survey Available
Request Chiller Specifications

Chiller description

Our 560kW chiller is highly energy efficient, has a dual circuit and multiple scroll compressors. It has internal free cooling controls and a remote probe as standard. This unit has a very compact footprint due to V bank design condensers.

The remote pump feed is integral on a panel mounted socket. It also has an integral flow switch so no separate assembly is required.

Lifting eyes, protective frames and fork pockets as standard. The operational temperature range is between -10°C upto +20°C.

The 560kW chiller is available to hire for planned or emergency requirements, 24/7. Call our team today for an instant quote.

Request chiller

0800 464 7025

Available 24/7

Chiller Hire Process

What our customers say

Specifications

Cooling capacity (kW)
557.14

Design Conditions (°C)
Ambient: 30 / Entering: 12/ Leaving: 7

E.E.R (kW/kW)
4.1

Refrigerant Gas (R)
454B

Compressor Type
Scroll

Number of Compressors (N°)
6

Number of Circuits
2

Total Compressors Nominal Absorbed Power (kW)
121.05

Total Compressor Running Current (RLA) (A)
196.92

Capacity Steps (N°)
4

Type of Evaporator
Shell and Tube

Nominal Flow Rate (m3/h)
95.54

Pressure Drops (kPa)
88.43

Incoming Pressure PRV (Bar)
6

System Volume (Litres)
160

Hydraulic Connections
4” Flange

Remote P3 Pump
Electrical Feed Included

Maximum Absorbed Current (FLA) (A)
26.6

Number of Condenser Coils (N°)
8

Number of Fans (N°)
8

Total Air Flow (m3/h)
164800

Nominal Absorbed Power (kW)
135.77

Maximum Absorbed Current (FLA) (A)
278.8

Maximum Starting Current (LRA) (A)
559.6

Plug type
Hard Wired

Electrical feed (V/ph/Hz)
400/3/50 + E (No Neutral)

Length (mm)
5900

Width (mm)
2220

Height (mm)
2604

Empty Weight (kg)
3950

Industry sectors

Take a look at the sectors that use this capacity chiller

Leisure & Tourism

Learn More

Facilities Management

Learn More

Education

Learn More
Planned Chiller Hire
Planned Chiller Hire

Are you working on a project that requires chillers? Arrange your free, comprehensive site survey and estimate today.

Emergency Chiller Hire
Emergency Chiller Hire

Do you need urgent chiller requirements to your building? We can be onsite within hours of receiving your call.

Call today for Emergency Chiller Hire 0800 464 7025

Available 24/7

  • ISO 9001 Logo
  • OFTEC Accredited Logo
  • CHAS Accredited Logo
  • Constructionline Gold Logo
  • GAS Safe Logo
  • SSIP Logo
  • F-Gass Certified
  • SafeContractor Logo