20kW DX Unit
20kW DX Unit

BS4343 (IEC 60309) 400V 5-pin 32A

20kW DX Unit

Weight

350kg

Dimensions (LxWxH)

1690mm × 1070mm × 1220mm

  • Rated 4.9/5 Stars on Feefo
  • Rapid Delivery & Installation
  • REFCOM F-Gas Certified
  • Highly Efficient Equipment
  • Brand New Equipment
  • 24/7/365 Support
  • Free Service Recovery Report
  • Free, No Obligation Estimate
Request Chiller Specifications

Chiller description

The Rapid Energy 20kW DX Air Cooled Air Conditioner provides efficient heating and cooling for commercial, industrial, and temporary HVAC applications. Compact and easy to deploy, it is ideal for maintaining controlled temperatures in smaller spaces or supporting existing climate control systems.

The unit delivers 20.2kW of cooling at 27°C indoor air temperature and 35°C ambient, and 20.8kW of heating at 20°C indoor air temperature, offering dependable year-round temperature control.

Designed as a self-contained direct expansion (DX) system, the unit uses a single refrigeration circuit to provide efficient performance with low noise levels. A simple control panel allows easy selection of heating or cooling modes and temperature setpoints, with optional Building Management System connectivity for monitoring and integration.

With plug-and-play power and duct connections, the unit can be installed quickly and used as a stand-alone solution or alongside Rapid Energy temperature control equipment to form a complete temporary heating or cooling system.

Request chiller

0800 464 7025

Available 24/7

  • I would like Rapid Energy to contact me as below. I acknowledge that I may withdraw my consent or unsubscribe at any time and that you will not pass my details to anyone. By clicking the Ok button I agree to the privacy policy

DX Unit Hire Process

What our customers say

Specifications

Cooling Capacity
20.2kW

Indoor Air Temperature (IAT) - Cooling
27°C

Cooling Ambient
35°C

Heating Capacity
20.8kW

Indoor Air Temperature (IAT) - Heating
20°C

Heating Ambient
7°C

Refrigerant Type
R410A

Refrigerant GWP
2088

Air/Ducting Connection (Outlets)
1 × 400mm

Volume Air Flow Rate (Design - Evap)
3000m³/hr

External Static Pressure (Design - Evap)
500Pa

Power Supply
400V / 3 / 50Hz

Absorbed Power (Max)
6.7kW

Current (FLA)
12.1amps

Power Connection
32amp Cee Form

Main Unit Dimensions (L × W × H)
1690mm × 1070mm × 1220mm

Unit Weight (Operating)
350kg

Industry sectors

Take a look at the sectors that use this capacity chiller

Residential Care Homes

Learn More

Facilities Management

Learn More

Education

Learn More
Planned Chiller Hire
Planned Chiller Hire

Are you working on a project that requires chillers? Arrange your free, comprehensive site survey and estimate today.

Emergency Chiller Hire
Emergency Chiller Hire

Do you need urgent chiller requirements to your building? We can be onsite within hours of receiving your call.

Call today for Emergency Chiller Hire 0800 464 7025

Available 24/7