50kW Chiller Hire
Heat exchanger
Air Handling Unit (AHU) used with Chiller
50kW Chiller Hire
Heat exchanger
Air Handling Unit (AHU) used with Chiller

(Performance 12/7°C – ambient 35°C)

50kW Chiller Hire

Weight

630kg

Dimensions (LxWxH)

2716mm x 1112mm x 1944mm

  • Rated 4.9/5 Stars on Feefo
  • Rapid Delivery & Installation
  • REFCOM F-Gas Certified
  • Highly Efficient Equipment
  • Brand New Equipment
  • 24/7/365 Support
  • Free Service Recovery Report
  • Free, No Obligation Estimate
Request Chiller Specifications

Chiller description

Trust the skilled and certified engineers at Rapid Energy, who are REFCOM F-GAS certified and experienced. With brand new equipment and a verified 5-star customer service, we provide a consistent and reliable chiller hire service.

Our modern and efficient 50kW Chiller is designed specifically for the hire industry, perfect for both process and comfort cooling. Whether you need it for planned or emergency scenarios, our chillers are ideal for various industry sectors such as contingency and emergency requirements, chemical & pharmaceutical, HVAC and building services, process cooling, low temperature requirements, food & beverage sectors, and more.

As a full turnkey hire solution, we offer complete services from surveying to commissioning a temporary chiller. Our team of engineers and project managers become an extension of your team and project.

With nationwide coverage in England, Scotland, and Wales, we provide 24/7 support throughout the duration of your hire. Hire with confidence by calling us today or requesting a call back through our short form below.

Request chiller

0800 464 7025

Available 24/7

Chiller Hire Process

What our customers say

Specifications

Cooling Capacity
55.90kW

Compressors absorobed power
15.14kW

Fluid to cool
Water

% of glycol
-

INLET evaporator water temperature
12°C

OUTLET evaporator water temperature
7°C

Air ambient temperature
35°C

Water flow
9.61 m3/h

Pressure drop
48 kPa

Refrigerant gas
R410a

Compressor/s
SCROLL

Compressors number / cooling circuit number
2 / 1 Nr.

Evaporator
PLATE

Evaporator number
1

Volume tank
300l

Pump type
P3

Pump Number
1 Nr.

Net prevalence
360 kPA

Fan Type
AXIAL

Fans number
2 Nr.

Fan Diameter
710mm

Fans Power
1.75kW

Sound pressure level at 10 mt from the condenser coil
48 dB(A)

Electrical voltage supply
400±10%/3/50 V/ph/Hz

FLI – absorbed power at full charge
29.10 kW

FLA – absorbed current at full charge
50.80 A

ICF – maximum Starting current
149.101 A

Length (mm)
2716mm

Width (mm)
1112mm

Height (mm)
1944mm

Weight (kg)
630

Connections
2” F GAS

Industry sectors

Take a look at the sectors that use this capacity chiller

Leisure & Tourism

Learn More

Facilities Management

Learn More

Education

Learn More
Planned Chiller Hire
Planned Chiller Hire

Are you working on a project that requires chillers? Arrange your free, comprehensive site survey and estimate today.

Emergency Chiller Hire
Emergency Chiller Hire

Do you need urgent chiller requirements to your building? We can be onsite within hours of receiving your call.

Call today for Emergency Chiller Hire 0800 464 7025

Available 24/7

  • ISO 9001 Logo
  • OFTEC Accredited Logo
  • CHAS Accredited Logo
  • Constructionline Gold Logo
  • GAS Safe Logo
  • SSIP Logo
  • F-Gass Certified
  • SafeContractor Logo